3745 Panel Codes
Table 1-5 (Page 18 of 33). Panel Codes. An
following a panel code denotes that the code should 'Blink'.
Panel
Code
Definition
Action: Go to “3745 FRU Group
Table” on page 1-49
or to MAP number
ACE
Moss level 0 error detection; Unexpected spurious inter-
rupt; PIO time out; No adaptor found with Last Priority
Level
Exchange the FRU group 9. Record
the following action for use if the
problem is not corrected by the FRU
exchange; A MOSS microcode
problem is suspected. Call your
support structure, refer to “Contacting
Support” on page A-1.
ACF
Moss level 0 error detection; Unexpected spurious inter-
rupt; PIO time out; Instruction was not an IO type
AD0
Moss level 0 error detection; Unexpected spurious inter-
rupt; PIO time out; Detected on level 2
AD1
Moss level 0 error detection; Unexpected spurious inter-
rupt; PIO time out; Detected on level 6
AD2
Moss level 0 error detection; Unexpected spurious inter-
rupt; Program request detected in PIRV
Exchange the FRU group 9. Record
the following action for use if the
problem is not corrected by the FRU
exchange; A MOSS microcode
problem is suspected. Call your
support structure, refer to “Contacting
Support” on page A-1.
AD3
Moss level 0 error detection; Unresolved Exception
error; Addressing exception during Instruction fetch
Exchange the FRU group 11. Record
the following action for use if the
problem is not corrected by the FRU
exchange; A MOSS microcode
problem is suspected. Call your
support structure, refer to “Contacting
Support” on page A-1.
AD4
Moss level 0 error detection; Unresolved Exception
error; Addressing exception during Main store data
access
AD5
Moss level 0 error detection; Unresolved Exception
error; Fixed point overflow exception
Exchange the FRU group 11. Record
the following action for use if the
problem is not corrected by the FRU
exchange; A MOSS microcode
problem is suspected. Call your
support structure, refer to “Contacting
Support” on page A-1.
AD6
Moss level 0 error detection; Unresolved Exception
error; Invalid address exception during non main store
access
AD7
Moss level 0 error detection; Unresolved Exception
error; Multiple bits detected in DIV
AD8
Moss level 0 error detection; Unresolved Exception
error; Multiple bits detected in EIRV
AD9
Moss level 0 error detection; Unresolved Exception
error; Operation exception; Invalid opcode detected
Exchange the FRU group 11. Record
the following action for use if the
problem is not corrected by the FRU
exchange; A MOSS microcode
problem is suspected. Call your
support structure, refer to “Contacting
Support” on page A-1.
ADA
Moss level 0 error detection; Unresolved Exception
error; Register precision exception
ADB
Moss level 0 error detection; Unresolved Exception
error;
Specification exception; Invalid address during Instruc-
tion fetch
ADC
Moss level 0 error detection; Unresolved Exception
error;
Specification exception; Invalid address during Main
store data access
( NOT ON level 2)
ADD
Moss level 0 error detection; Unresolved Exception
error;
Specification exception; Invalid address during non
GPR access
Exchange the FRU group 11. Record
the following action for use if the
problem is not corrected by the FRU
exchange; A MOSS microcode
problem is suspected. Call your
support structure, refer to “Contacting
Support” on page A-1.
ADE
Moss level 0 error detection; Unresolved Exception
error;
Specification exception; Invalid execution of KI instruc-
tion
ADF
Moss level 0 error detection; Unresolved Exception
error;
Specification exception; PSV bits (40-44-47) are not
zero
AE0
Moss level 0 error detection; Unresolved Internal
Check; Cache
register parity check
1-32 3745 Models 130 to 17A: MIP