CE leaving procedure
CA Restore Procedure
1. On the 3745 console, invoke Menu 3 and type CAS in the selection area for channel adapter services.
2. Press SEND.
3. Type 4 for concurrent maintenance commands.
4. Press SEND.
5. Type the channel adapter number corresponding to this FRU in the CA number ===> field.
6. Press SEND
7. Type RES in the command ===>field.
8. Press SEND.
9. Re-initiate the same procedure from Step 5 for the associated CA, if any.
How to Put the MOSS Online
Note: MOSS can only be put online if the NCP is running.
1. Using the console, invoke Menu 2 (See PF key line).
2. In Menu 2, type MON in the selection area.
3. Press SEND.
4. MOSS ONLINE will be displayed on the screen.
TRA Reconnect Procedure: For this procedure you may wish to refer to Figure 1-6 on
page 1-67, Figure 1-8 on page 1-68, and Figure 1-7 on page 1-67.
1. On the 3745 console, invoke Menu 3 (See PF key line).
2. In Menu 3 type TRS in the selection area for TRSS services.
3. Press SEND.
4. The TRSS Function Selection Screen is displayed.
5. Type 1 in the selection area for TRA Selection Screen.
6. Press SEND.
7. The TRA Selection Screen is displayed.
8. Type the TRA number in the TRA # ==> field.
9. Press SEND
10. The TRSS Function Selection Screen is displayed.
11. Type 2 in the selection area for Connect/Disconnect.
12. Press SEND.
13. The TRA Connect/Disconnect Selection Screen is displayed.
14. Type CT in the input area to connect the selected adapter to the NCP.
15. Press SEND.
16. Re-initiate the same procedure from Step 5 for the associated TRA, if any.
Chapter 4. 3745 FRU Exchange 4-105