Disabling Procedures
Disabling Procedure 0120: Preparing a TSS/HPTSS/ESS for
Maintenance
Important
Before using this procedure, ensure that the
MOSS is online. If at this time MOSS is
offline, set MOSS online to perform this proce-
dure. Refer to “How to Put the MOSS Online”
on page 4-105 for more information.
If you are coming from MAP 2100 or MAP 2130,
go to Step 002.
001
Is the FRU a CSP card (CSP is one of the 2
HPTSS/ESS cards) ?
Yes No
002
1. Ask the customer to deactivate all the
lines attached to the line adapter
(recorded as affected lines).
Wait until the customer has completed
deactivating the lines.
2. Using the 3745 console, disconnect the
line adapter from the NCP as follows:
a. From menu 3, select TSS Services
by entering TSS in the selection
area.
b. From the TSS Services screen,
choose select/release by entering 1
in the selection area. See
Figure 1-2 on page 1-63.
c. In the input area, enter an S fol-
lowed by the line adapter number.
See Figure 1-3 on page 1-63.
d. Enter 3 in the selection area to
choose Mode Control.
e. If, in the MSA display (upper part of
the screen), the status of the
scanner is Unknown Mode, then
enter RT on the Mode Control
screen enter and continue with the
next Step 2f
f. On Mode Control screen, enter DS
to disconnect the line adapter. See
Figure 1-4 on page 1-64.
If deactivation of all the lines driven
by this line adapter was not done, a
screen showing the still active lines
will be displayed. If the customer is
unable to deactivate these lines,
request his approval to force deacti-
vation for these lines.
To force deactivation, enter F on the
displayed screen.
Continue with the next step only
when all lines have been deacti-
vated and the line adapter has been
disconnected.
g. Enter 1 in the selection area to
choose select/release. See
Figure 1-2 on page 1-63.
h. Enter REL in the input area to
release the disabled line adapter.
See Figure 1-3 on page 1-63.
Run the requested diagnostics (TSS,
HPTSS, or ESS).
Refer to Figure 1-5 on page 1-64. If nec-
essary, refer to “How to Run Internal Func-
tion Tests” on page 3-9. Then go to
“Diagnostic and Exchange Result Analysis
0000” on page 4-99
003
The entire machine is required. Ask the customer
to deactivate all the lines attached to the 3745
and to deactivate NCP. Then refer to “How to
Run Internal Function Tests” on page 3-9.
Note: You must never run the HPTSS/ESS diag-
nostics under concurrent maintenance
before exchanging a probably defective
CSP card. This would cause other line
adapters to go down.
1-62 3745 Models 130 to 17A: MIP