3745 Panel Codes
Table 1-5 (Page 3 of 33). Panel Codes. An
following a panel code denotes that the code should 'Blink'.
Panel
Code
Definition
Action: Go to “3745 FRU Group
Table” on page 1-49
or to MAP number
076
SOME ERROR(S) OCCURRED DURING THE PIO
BUS TEST PARTICULARLY ON DFA I/Os AND ON
MCCU OR MCAD I/Os ON MCC.
Exchange the FRU group 8
077
SOME ERROR(S) OCCURRED DURING THE PIO
BUS TEST PARTICULARLY ON MPC I/Os AND ON
DFA I/Os AND ON MCCU OR MCAD I/Os ON MCC.
Exchange the FRU group 6
078
SOME ERROR(S) OCCURRED DURING THE PIO
BUS TEST PARTICULARLY ON PCA'S I/Os ON MCC
Exchange the FRU group 3
079
SOME ERROR(S) OCCURRED DURING THE PIO
BUS TEST PARTICULARLY ON MPC AND PCA'S I/Os
ON MCC
Exchange the FRU group 1
.
07A
SOME ERROR(S) OCCURRED DURING THE PIO
BUS TEST PARTICULARLY ON DFA AND PCA'S I/Os
ON MCC
Exchange the FRU group 8
07B
SOME ERROR(S) OCCURRED DURING THE PIO
BUS TEST PARTICULARLY ON MPC I/Os , DFA I/Os
AND PCA'S I/Os ON MCC.
Exchange the FRU group 6
07C
SOME ERROR(S) OCCURRED DURING THE PIO
BUS TEST PARTICULARLY ON MCC I/Os
(MCCU,MCAD AND PCA'S).
Exchange the FRU group 3
07D
SOME ERROR(S) OCCURRED DURING THE PIO
BUS TEST PARTICULARLY ON MPC AND MCC I/Os.
Exchange the FRU group 1
.
07E
SOME ERROR(S) OCCURRED DURING THE PIO
BUS TEST PARTICULARLY ON DFA AND MCC I/Os.
Exchange the FRU group 8
07F
SOME ERROR(S) OCCURRED DURING THE PIO
BUS TEST ERRORS WERE DETECTED ON ALL
ADAPTERS
Exchange the FRU group 1
.
080 to 096 Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
097
PIO TEST PART 1 SUCCESSFUL PROBLEM IN PIO
BUS TEST PART 2
Exchange the FRU group 9
098 PIO TEST PART 2 NOT SUCCESSFUL Exchange the FRU group 5
099 PIO TEST PART 2 SUCCESSFUL Progression code.
If permanently displayed, exchange
the FRU group 2
09A to 09C Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
09D PROBLEM WITH PCC Exchange the FRU group 12
09E
INFORMATION DEFINING THE ORIGIN OF THE
ACTIVATION OF THE MOSS DIAGNOSTICS IS NOT
VALID. (RUN THE PANEL TEST TO CHECK THE
CONTROL PANEL).
Exchange the FRU group 10
09F
CONTROL LOST IN THE MAINLINE CONTROLLER
AFTER CHECKING THE REQUEST
Exchange the FRU group 2
0A0
MOSS STORAGE TEST ENTRY CODE Progression
code.
If permanently displayed, exchange
the FRU group 2
0A1 EIRV REGISTER IS NOT X'00' IN TEST 1 Exchange the FRU group 2
0A2 EIRV REGISTER IS NOT X'00' IN TEST 2 Exchange the FRU group 11
0A3 DISABLE THE VALID OPTION KO IN TEST 1 Exchange the FRU group 12
0A4
RECONFIGURE BIT IS ALWAYS 'ON' IN TOD
ADAPTER
Exchange the FRU group 13
0A5 ADDRESS NOT INCREMENTED IN TEST 2 Exchange the FRU group 13
0A6
DIFFERENT LOADED AND STORED CONTENTS IN
TEST 2
Exchange the FRU group 11
0A7 INVALID ADDRESS IN THE ROS IN TEST 2 Exchange the FRU group 13
0A8
INVALID ADDRESS AFTER 512K OR 1MEG IN TEST
2
Exchange the FRU group 13
0A9
NO MEMORY LOCATION WITHOUT ERROR IS
FOUND IN TEST 2
Exchange the FRU group 11
0AA EIRV REGISTER IS NOT X'00' IN TEST 4 Exchange the FRU group 13
0AB to 0AC Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
Chapter 1. START: How to Begin Troubleshooting 1-17