IBM ibm Home Theater Server User Manual


 
3745 Panel Codes
Table 1-5 (Page 29 of 33). Panel Codes. An
following a panel code denotes that the code should 'Blink'.
Panel
Code
Definition
Action: Go to “3745 FRU Group
Table” on page 1-49
or to MAP number
F18
Errors detected during the IPL sequence; IOC BUS test
failed
A reference code will have been
produced on the 3745 console. Refer
to “Using Reference Codes” on
page 1-14.
F19
Errors detected during the IPL sequence; IPL port table
has been incorrectly built via the CDF
F1A
Errors detected during the IPL sequence; CLDP not
accessible
F1B
Errors detected during the IPL sequence; CLDP/SALT
abend. (output 70)
F1C
Errors detected during the IPL sequence; CLDP/MOSS
interface error
A reference code will have been
produced on the 3745 console. Refer
to “Using Reference Codes” on
page 1-14.
F1D
Errors detected during the IPL sequence; NCP/EP init
abend
F1E
Errors detected during the IPL sequence; CLDP time
out on 'IN MAILBOX' acknowledgement
F1F
Errors detected during the IPL sequence; MOSS time
out on waiting NCP/EP init MB out
F20
Errors detected during the IPL sequence; MOSS time
out on waiting NCP/EP init MB in acknowledgement
A reference code will have been
produced on the 3745 console. Refer
to “Using Reference Codes” on
page 1-14.
F21
Errors detected during the IPL sequence; NCP/EP
INIT/MOSS interface error acknowledgement
F22 to F23 Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
F24
Errors detected during the IPL sequence; no scanner
IMLed after scanner IML routine (Phase 3)
A reference code will have been
produced on the 3745 console. Refer
to “Using Reference Codes” on
page 1-14.
F25
Errors detected during the IPL sequence; no valid
scanner in CDS
F26
Errors detected during the IPL sequence; LSSD resi-
dual count > 7
F27
Errors detected during the IPL sequence; LSSD string
select error during a read or write LSSD
F28
Errors detected during the IPL sequence; IPL phase 1A
load module not accessible
There is a defect with the hard disk.
Contact your support structure, refer
to “Contacting Support” on page A-1.
F29
Errors detected during the IPL sequence; IPL phase 1B
load module not accessible
F2A
Errors detected during the IPL sequence; IPL phase 2
load module not accessible
F2B
Errors detected during the IPL sequence; IPL phase 3
load module not accessible
F2C
Errors detected during the IPL sequence; IPL phase 4
load module not accessible
F2D
Errors detected during the IPL sequence; too many
CCU RE-IPL (PGM abend or hardcheck)
A reference code will have been
produced on the 3745 console. Refer
to “Using Reference Codes” on
page 1-14.
F2E
Errors detected during the IPL sequence; wrong CCU
LSSD initialization
F2F
Errors detected during the IPL sequence; no IPL port is
available (neither link nor channel) and no load module
on the disk is available
F30
Errors detected during the IPL sequence; CPIT error:
CPIT length different from CHGCONCP
Some CPIT fields not initialized
F31
Errors detected during the IPL sequence; IPL phase 1C
load module not accessible
F32
Errors detected during the IPL sequence; CCU check
occurred during phase 1C
F33
Errors detected during the IPL sequence; SALT not
accessible
F34
Errors detected during the IPL sequence; CCU memory
failure
F35
Errors detected during the IPL sequence; Dispcrepancy
between CLDP and 3746-900 CDF information
Chapter 1. START: How to Begin Troubleshooting 1-43