3745 Panel Codes
Table 1-5 (Page 32 of 33). Panel Codes. An
following a panel code denotes that the code should 'Blink'.
Panel
Code
Definition
Action: Go to “3745 FRU Group
Table” on page 1-49
or to MAP number
FF0
Status/progression step which occur during the IPL
sequence; IPL entered
If this code is displayed for more than
2 minutes, then a MOSS microcode
problem is suspected.
Contact your support structure,
refer to “Contacting Support” on
page A-1.
FF1
Status/progression step which occurs during the IPL
sequence; IPL phase 1 started
FF2
Status/progression step which occurs during the IPL
sequence; IPL phase 2 started
FF3
Status/progression step which occurs during the IPL
sequence; IPL phase 3 entered
FF4
Status/progression step which occurs during the IPL
sequence; IPL phase 4 entered
If this code is displayed for more than
2 minutes when:
1. The load/dump is via a channel,
then go to “MAP 3500:
Activate/Deactivate Line Problem
or Line Errors on the TSS” on
page 2-7.
2. The load/dump is via the disk,
then run “How to Run MOSS
Diagnostics” on page 3-4 to aid
problem isolation and refer to
IBM
3745 Service Functions
, "Hard
Disk Trouble Analysis".
OR
if this code is displayed for more than
10 - 20 minutes (depending on IPL
link speed) when:
3. The load/dump is via a link, then
follow carefully the PD Guide.
FF5
Status/progression step which occurs during the IPL
sequence; the control program load/dump is started on
a channel-attached 3745
If this code is displayed for more than
2 minutes, then go to “MAP 3500:
Activate/Deactivate Line Problem or
Line Errors on the TSS” on page 2-7.
FF6
Status/progression step which occurs during the IPL
sequence; the control program load/dump is started on
a link-attached 3745
If this code is displayed for more than
10 - 20 minutes (depending on IPL
link speed) then follow the PD guide.
FF7
Status/progression step which occurs during the IPL
sequence; control program is loaded and initialization
has started
If this code is displayed for more than
2 minutes, then the CCU failed to ini-
tialize the control program. A control
program problem is suspected.
Contact your support structure, refer
to “Contacting Support” on page A-1.
FF8
Status/Progression step which occurs during the IPL
sequence; control program Load/Dump is started on a
ESCA attached 3756-900.
No action required
FF9 Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
FFA
Status/progression step which occurs during the IPL
sequence; IPL has completed but has detected a PCA1
adapter error; local console may not be accessible
Go to “How to Run the Console Link
Test for 3745 Models 130, 150, 160,
and 170” on page 3-6 and run the
local console link test. Record:
exchange the FRU group 26 for pos-
sible exchange if problem still exists.
FFB
Status/progression step which occurs during the IPL
sequence; IPL was cancelled by the 3745 console
operator
No action required
FFC Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
FFD
Status/progression step which occurs during the IPL
sequence; IPL has completed; The MOSS IML was per-
formed from the diskette; the control program is loaded
and MOSS is operational
No action required
FFE
Status/progression step which occurs during the IPL
sequence; IPL has been completed but has detected
some error during the sequence.
A reference code will have been
produced on the 3745 console. Refer
to “Using Reference Codes” on
page 1-14.
1-46 3745 Models 130 to 17A: MIP