3745 MAPs
MAP 3910: Overcurrent on Power Supply 2
Symptom Explanation Conditions That Could Cause This Symptom
Overcurrent on power supply 2. Short circuit in:
Fan1
Fan2
PCC
Panel
PS2
001
Unplug the FAN1 power cable 01H-B1-J7 from
PS2.
Power the 3745 ON as follows:
put the power control in local mode:
Using Power Control, scroll till the
value is 3.
Press Validate.
Press Power On Reset.
Is the panel code 00E still displayed?
Yes No
002
Press Power Off.
Exchange the Fan1. Go to “Fan 1
Exchange Procedure” on page 4-50.
003
Replug the Fan1 power cable.
Unplug the Fan2 power cable (01H-B1-J6) from
PS2.
Power the 3745 ON as follow:
Put the power control in local mode:
Using Power Control, scroll till the
value is 3.
Press Validate.
Press Power On reset.
Is the panel code 00E still displayed?
Yes No
004
Press Power Off.
Exchange the Fan2. Go to “Fan 2
Exchange Procedure” on page 4-51.
005
Replug the Fan2 power cable.
Exchange the PCC card (01A-X0B). Go to
“Card Exchange Procedure” on page 4-34.
Press Power On Reset.
(Step 005 continues)
005 (continued)
Is the panel code 00E still displayed?
Yes No
006
Go to “CE Leaving Procedure” on
page 4-102.
007
Exchange the control panel. Go to “Control
Panel Exchange Procedure” on page 4-46.
Press Power On Reset.
Is the panel code 00E still displayed?
Yes No
008
Go to “CE Leaving Procedure” on
page 4-102.
009
Exchange the PS2. Go to “PS2 and Primary
Power Box Exchange Procedure” on page 4-69.
2-18 3745 Models 130 to 17A: MIP