IBM ibm Home Theater Server User Manual


 
3745 Panel Codes
Table 1-5 (Page 8 of 33). Panel Codes. An
following a panel code denotes that the code should 'Blink'.
Panel
Code
Definition
Action: Go to “3745 FRU Group
Table” on page 1-49
or to MAP number
135
EIRV REGISTER IS NOT X'00' IN TEST 13 ECC COR-
RECTION TEST
Exchange the FRU group 16
136
DATA TRANSMISSION ERROR HSTAT BITS
0,1,2,3,6,7 ARE NOT ZERO ECC CORRECTION TEST
137
ERROR ON A SELECTED SECTOR ECC COR-
RECTION TEST
138
NO ERROR IN SSB WHILE EXPECTED ECC COR-
RECTION TEST
139 NO CORRECTION ECC CORRECTION TEST
Exchange the FRU group 16
13A NO DETECTION ECC CORRECTION TEST
13C ERROR SSB BYTE 0 ECC CORRECTION TEST
13D
ERROR SSB BYTE 1 AND 2 ECC CORRECTION
TEST
13E
DIFFERENT WRITTEN AND READ CONTENTS IN
TEST 13
Exchange the FRU group 16
13F
DISKETTE CHANGE INFORMATION IS NOT
PRESENT
Exchange the FRU group 18
140
ADAPTER IN BUSY STATE IN TEST 5 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE DRIVES INITIALIZATION
DISKETTE
Exchange the FRU group 17
141
IOIRV REGISTER IS X'00' IN TEST 5 NO INTER-
RUPT RECEIVED DRIVES INITIALIZATION DISKETTE
Exchange the FRU group 19
142
EIRV REGISTER IS NOT X'00' IN TEST 5 DRIVES
INITIALIZATION DISKETTE
Exchange the FRU group 17
143
DATA TRANSMISSION ERROR HSTAT BITS
0,1,2,3,6,7 ARE NOT ZERO DRIVES INITIALIZATION
DISKETTE
Exchange the FRU group 19
144
ADAPTER IN BUSY STATE IN TEST 6 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE SEEK COMMAND
BEFORE RECALIBRATE TEST DISKETTE
Exchange the FRU group 17
145
IOIRV REGISTER IS X'00' IN TEST 6 NO INTER-
RUPT RECEIVED SEEK COMMAND BEFORE
RECALIBRATE TEST DISKETTE
Exchange the FRU group 19
146 Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
147
ADAPTER IN BUSY STATE IN TEST 6 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE RECALIBRATE COMMAND
TEST DISKETTE
Exchange the FRU group 17
148
IOIRV REGISTER IS X'00' IN TEST 6 NO INTER-
RUPT RECEIVED RECALIBRATE COMMAND TEST
DISKETTE
Exchange the FRU group 17
149
EIRV REGISTER IS NOT X'00' IN TEST 6 RECALI-
BRATE COMMAND TEST DISKETTE
Exchange the FRU group 19
14A
DATA TRANSMISSION ERROR HSTAT BITS
0,1,2,3,6,7 ARE NOT ZERO DRIVES INITIALIZATION
RECALIBRATE COMMAND TEST DISKETTE OR NO
DISKETTE (OR BAD DISKETTE) IN DRIVE
Exchange the FRU group 21
14B
NO CYLINDER ZERO IN SSB BYTE0 BIT 7 RECALI-
BRATE COMMAND TEST2DRIVE DISKETTE
14C
ERROR IN SSB BYTE 0 RECALIBRATE COMMAND
TEST DISKETTE
14D
ERROR IN SSB BYTE 1 AND 2 RECALIBRATE
COMMAND TEST DISKETTE
14E
ADAPTER IN BUSY STATE IN TEST 7 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE READ ID COMMAND TEST
DISKETTE
Exchange the FRU group 17
1-22 3745 Models 130 to 17A: MIP