IBM ibm Home Theater Server User Manual


 
3745 Panel Codes
Table 1-5 (Page 6 of 33). Panel Codes. An
following a panel code denotes that the code should 'Blink'.
Panel
Code
Definition
Action: Go to “3745 FRU Group
Table” on page 1-49
or to MAP number
0F7
EIRV REGISTER IS NOT X'00' IN TEST 7 READ ID
COMMAND TEST
Exchange the FRU group 16
0F8
DATA TRANSMISSION ERROR HSTAT BITS
0,1,2,3,6,7 ARE NOT ZERO READ ID COMMAND
TEST
0F9
ERROR ON HEAD ADDRESSING MECHANISM READ
ID COMMAND TEST
0FA ERROR IN SSB BYTE 0 READ ID COMMAND TEST
0FB
ERROR IN SSB BYTE 1 AND 2 READ ID COMMAND
TEST
Exchange the FRU group 16
0FC
ADAPTER IN BUSY STATE IN TEST 8 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE RECALIBRATE COMMAND
BEFORE SEEK TEST
0FD
IOIRV REGISTER IS X'00' IN TEST 8 NO INTER-
RUPT RECEIVED RECALIBRATE COMMAND
BEFORE SEEK TEST
0FE Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
0FF
ADAPTER IN BUSY STATE IN TEST 8 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE SEEK COMMAND TEST
Exchange the FRU group 16
100 Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
101
HARD DISK INITIAL STATE IS NOT OK. A
RECOVERY PROCEDURE IS RUNNING.
Exchange the FRU group 16
102
HARD DISK INITIAL STATE NOT OK (EVEN AFTER
A RECOVERY PROCEDURE).
103 to 110 Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
111
IOIRV REGISTER IS X'00' IN TEST 8 NO INTER-
RUPT RECEIVED SEEK COMMAND TEST
Exchange the FRU group 16
112
EIRV REGISTER IS NOT X'00' IN TEST 8 SEEK
COMMAND TEST
113
DATA TRANSMISSION ERROR HSTAT BITS
0,1,2,3,6,7 ARE NOT ZERO SEEK COMMAND TEST
114
DIFFERENT HEAD NUMBERS SEEK COMMAND
TEST
115 ERROR IN SSB BYTE 0 SEEK COMMAND TEST
Exchange the FRU group 16
116
ERROR IN SSB BYTE 1 AND 2 SEEK COMMAND
TEST
117
ADAPTER IN BUSY STATE IN TEST 9 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE READ/WRITE A SECTOR
COMMAND
118
IOIRV REGISTER IS X'00' IN TEST 9 NO INTER-
RUPT RECEIVED READ/WRITE A SECTOR
COMMAND
119
EIRV REGISTER IS NOT X'00' IN TEST 9
READ/WRITE A SECTOR COMMAND
Exchange the FRU group 16
11A
DATA TRANSMISSION ERROR HSTAT BITS
0,1,2,3,6,7 ARE NOT ZERO READ/WRITE A SECTOR
COMMAND
11B
DIFFERENT WRITTEN AND READ SECTORS
READ/WRITE A SECTOR COMMAND
11C
ERROR IN SSB BYTE 0 READ/WRITE A SECTOR
COMMAND
1-20 3745 Models 130 to 17A: MIP