3745 MAPs
021 (continued)
– Replug the LIB1 power cable.
– Unplug the LIB2 or LIB1 power cable 01F-A1J7
from PS1. if any. If there is no cable go to Step
027.
– Press Power On Reset.
Is the panel code 00B still displayed?
Yes No
022
– Replug the LIB2 or LIB1 power cable.
– Unplug all LICs of LIB1 or LIB2 from
01L-A2C2 to 01L-A2K2 with their cables.
– Press Power On Reset.
Is the panel code 00B still displayed?
Yes No
023
– Replug the LICs one by one and
exchange the faulty one. Go to
“LIC Exchange Procedure” on
page 4-44.
024
– Unplug the SMUX or DMUX (01L-A2B2)
with its cables.
– Press Power On Reset.
Is panel code 00B still displayed?
Yes No
025
– Exchange the SMUX. Go to
“SMUXA/B Exchange Procedure”
on page 4-41.
– For the DMUX go to “DMUX
Exchange Procedure” on
page 4-39.
026
– Exchange the LIB1 (01M-A1). Go to “LIC
Board Type 1 and 3 Exchange
Procedure” on page 4-84.
– or exhange the LIB2. Go to “LIC Board
Type 2 Exchange Procedure” on
page 4-88.
027
– Replug LIB2 or LIB1 power cable.
– Unplug LIB1 power cable 01F-A1J8 from PS1.
– Press Power On Reset.
Is the panel code 00B still displayed?
Yes No
028
(Step 028 continues)
028 (continued)
– Replug the LIB2 power cable.
– Unplug all LICs from LIB2 from 01L-A1C2
to 01L-A1K2 with their cables.
– Press Power On Reset.
Is the panel code 00B still displayed?
Yes No
029
– replug the LICs one by one and
exchange the faulty one. Go to
“LIC Exchange Procedure” on
page 4-44.
030
– Unplug the SMUX (01L-A1B2) with its
cables.
– Press Power On Reset.
Is the panel code 00B still displayed?
Yes No
031
– Exchange the SMUX. Go to
“SMUXA/B Exchange Procedure”
on page 4-41.
032
– Exchange the LIB2 (01L-A1). Go to “LIC
Board Type 2 Exchange Procedure” on
page 4-88.
033
– Replug the LB1 power cable
– Unplug the MOSS cards (from 01A-X0E to
01A-X0H). Do not remove the PCC card
(01A-X0B).
– Press Power On Reset.
Is the panel code 00B still displayed?
Yes No
034
– Press Power Off.
– Replug the MOSS card by card and try to
power 3745 ON after each one.
– Exchange the faulty card you replugged
when the over current appeared.
035
– Exchange the PCC card (01A-X0B). Go to
“Card Exchange Procedure” on page 4-34.
Is the panel code 00B still displayed?
Yes No
036
Go to “CE Leaving Procedure” on
page 4-102.
2-14 3745 Models 130 to 17A: MIP