IBM ibm Home Theater Server User Manual


 
3745 FRU Exchange Procedure
Battery Exchange Procedure
It is the Service Personnels responsibility to
exchange the battery.
The 3745 will automatically send an alert to the
operator console when there is a need to
exchange the battery.
Removal Procedure
1. Locate the control panel. Refer to
Figure 4-62.
2. Open the front door.
3. Open the control panel door (one screw must
be removed).
4. Locate the battery 1. Refer to Figure 4-63.
5. Remove the tie wrap on the battery and dis-
connect the battery plug 2.
Figure 4-62. Panel Location
Installation Procedure
1. Insert the new battery and reconnect the plug.
2. Fasten the tie wrap to the battery.
3. Close the control panel door with the screw.
4. Close the front door.
J 1
Figure 4-63. Battery Location
5. Battery disposal must be performed
according to the instruction on the battery
case.
Reporting: Update the battery exchange
record as follows:
Using the 3745 console, type POS on any dis-
played screen selection area for Power Ser-
vices Screen.
Press SEND.
The Power Services Screen is displayed.
Refer to Figure 4-64 on page 4-49. If a
MOSS console function is in process, press
the F1 key to terminate.
Type 2 in the selection area for Battery
change acknowledge.
Press SEND.
The Battery Change Screen is displayed.
Refer to Figure 4-65 on page 4-49.
Type Y in the CONFIRM THAT THE
BATTERY HAS BEEN CHANGED (Y/N) ==>
field.
Press SEND.
A successful command message will appear.
Go to “CE Leaving Procedure” on page 4-102 for
the time update.
Note: If the code 007 is displayed on the 3745
control panel, a MOSS IML (function 1)
should be performed to reset this code.
4-48 3745 Models 130 to 17A: MIP