IBM ibm Home Theater Server User Manual


 
3745 Panel Codes
Table 1-5 (Page 5 of 33). Panel Codes. An
following a panel code denotes that the code should 'Blink'.
Panel
Code
Definition
Action: Go to “3745 FRU Group
Table” on page 1-49
or to MAP number
0DF
IOIRV REGISTER IS X'00' IN TEST 2 NO INTER-
RUPT REQUESTED
Exchange the FRU group 15
0E0 CHIO TRANSFER KO
0E1
ADAPTER IN BUSY STATE IN TEST 4 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE RUN DIAGNOSTIC
COMMAND TEST
0E2
DATA TRANSMISSION ERROR HSTAT BITS
0,1,2,3,6,7 ARE NOT ZERO RUN DIAGNOSTIC
COMMAND TEST
0E3
DIFFERENT CONTENTS IN THE FIRST AND THE
SECOND PART OF THE SECTOR BUFFER RUN
DIAGNOSTIC COMMAND TEST
Exchange the FRU group 15
0E4
ERROR IN SSB BYTE 0 RUN DIAGNOSTIC
COMMAND TEST
Exchange the FRU group 21
0E5
ERROR IN SSB BYTE 1 AND 2 RUN DIAGNOSTIC
COMMAND TEST
Exchange the FRU group 15
0E6
ADAPTER IN BUSY STATE IN TEST 5 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE DRIVES INITIALIZATION
Exchange the FRU group 16
0E7
IOIRV REGISTER IS X'00' IN TEST 5 NO INTER-
RUPT RECEIVED DRIVES INITIALIZATION
0E8
EIRV REGISTER IS NOT X'00' IN TEST 5 DRIVES
INITIALIZATION
0E9
DATA TRANSMISSION ERROR HSTAT BITS
0,1,2,3,6,7 ARE NOT ZERO DRIVES INITIALIZATION
0EA
ADAPTER IN BUSY STATE IN TEST 6 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE SEEK COMMAND
BEFORE RECALIBRATE TEST
Exchange the FRU group 16
0EB
IOIRV REGISTER IS X'00' IN TEST 6 NO INTER-
RUPT RECEIVED SEEK COMMAND BEFORE
RECALIBRATE TEST
0ED
ADAPTER IN BUSY STATE IN TEST 6 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE RECALIBRATE COMMAND
TEST
0EE
IOIRV REGISTER IS X'00' IN TEST 6 NO INTER-
RUPT RECEIVED RECALIBRATE COMMAND TEST
0EF
EIRV REGISTER IS NOT X'00' IN TEST 6 RECALI-
BRATE COMMAND TEST
Exchange the FRU group 16
0F0 Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
0F1
DATA TRANSMISSION ERROR HSTAT BITS
0,1,2,3,6,7 ARE NOT ZERO DRIVES INITIALIZATION
RECALIBRATE COMMAND TEST
Exchange the FRU group 16
0F2
NO CYLINDER ZERO IN SSB BYTE0 BIT 7 RECALI-
BRATE COMMAND TEST
0F3
ERROR IN SSB BYTE 0 RECALIBRATE COMMAND
TEST
Exchange the FRU group 16
0F4
ERROR IN SSB BYTE 1 AND 2 RECALIBRATE
COMMAND TEST
0F5
ADAPTER IN BUSY STATE IN TEST 7 BSTAT BITS
0,1 ARE NOT B'00' OR ADAPTER NOT ENABLE
BSTAT BIT 6 IS NOT ONE READ ID COMMAND TEST
0F6
IOIRV REGISTER IS X'00' IN TEST 7 NO INTER-
RUPT RECEIVED READ ID COMMAND TEST
Chapter 1. START: How to Begin Troubleshooting 1-19