3745 Panel Codes
Table 1-5 (Page 11 of 33). Panel Codes. An
following a panel code denotes that the code should 'Blink'.
Panel
Code
Definition
Action: Go to “3745 FRU Group
Table” on page 1-49
or to MAP number
1A4
REMOTE/ALTERNATE CONSOLE CABLE DOWN
(WHEN WRAP BLOCK INSTALLED)
Exchange the FRU group 29
1A5 REMOTE/ALTERNATE CONSOLE PCA ERROR Exchange the FRU group 26
1A6
WRAP BLOCK DOES NOT SEEM TO BE PRESENT
ON RSF PORT , OR SIGNALS TESTED ARE NOT
OK.
Exchange the FRU group 27
1A7
RSF CONSOLE CABLE DOWN (WHEN WRAP BLOCK
INSTALLED)
Exchange the FRU group 30
1A8 RSF CONSOLE PCA ERROR Exchange the FRU group 26
1A9 TO
1AF
Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
1B0 COMPLETION OF MCC TEST Progression code.
If permanently displayed, exchange
the FRU group 2
1B1 START OF LOCAL CONSOLE LINK TEST
INFORMATION ONLY
1B2 SUCCESSFUL LOCAL CONSOLE LINK TEST
1B3 START OF REMOTE/ALT CONSOLE LINK TEST
1B4 SUCCESSFUL REMOTE /ALT CONSOLE LINK TEST
1B5 START OF RSF CONSOLE LINK TEST
INFORMATION ONLY
1B6 SUCCESSFUL RSF CONSOLE LINK TEST
1B7 to 1B9 Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
1D0 START OF MCAC TEST.Progression code.
If permanently displayed, exchange
the FRU group 2
1D1 Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
1D2 SOLID ERROR IN MCAD REGISTERS (1 FRU )
Exchange the FRU group 26
1D3 100 MS TIMER OF MCAD KO
1D4 PERMANENT IR 1 IN IOIRV
Exchange the FRU group 5
1D5 PERMANENT IR 4 IN IOIRV
1D6
IR LEVEL 1 OF MCAD NOT REPORTED TO MOSS
PROCESSOR.
1D7
'MOSS INOP BIT' NOT ON AFTER RESET BY THE
RESET LINE IN MCCU
Exchange the FRU group 26
1D8 Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
1D9 PERMANENT IR 0 IN IOIRV
Exchange the FRU group 5
1DA SOLID ERROR IN MCCU REGISTERS
1DB SOLID ERROR IN MCCU REGISTERS Exchange the FRU group 26
1DC to
1DF
Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
1E0 IOC TAG RESET FUNCTION KO
Go to “MAP 0100: IOC Bus Trouble
Shooting” on page 2-1
1E1 Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
1E2 WATCHDOG INTERRUPT BIT ON IN MCCU Exchange the FRU group 26
1E3 MOSS INOP BIT NOT SETTABLE IN MCCU Exchange the FRU group 5
1E4 to 1E6 Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
1E7 NO INTERRUPT REPORTING POSSIBLE IN MCCU Exchange the FRU group 26
1E8 to 1EE Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
1EF END OF MCAC TEST Progression code.
If permanently displayed, exchange
the FRU group 2
1F0 to 1FD Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
1FE Control lost during return to RAM IML processor Exchange the FRU group 25
1FF Completion of MOSS diagnostics RAM part Exchange the FRU group 2