IBM ibm Home Theater Server User Manual


 
3745 Panel Codes
Table 1-5 (Page 10 of 33). Panel Codes. An
following a panel code denotes that the code should 'Blink'.
Panel
Code
Definition
Action: Go to “3745 FRU Group
Table” on page 1-49
or to MAP number
17E Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
17F
COMPLETION OF ROS PART OF MOSS DIAGNOS-
TICS Progression code.
If permanently displayed, exchange
the FRU group 24
180
ENTRY INTO RAM PART OF MOSS DIAGNOSTICS
Progression code.
If permanently displayed, exchange
the FRU group 25
181
CURRENT PROGRAM LEVEL NOT AS EXPECTED
(SHOULD HAVE BEEN 6)
Exchange the FRU group 25
182
RAM DIAG CONTROLLER HAS FULL CONTROL
Progression code.
If permanently displayed, exchange
the FRU group 25
183 to 187 Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
188
CONTROL LOST DURING INSTRUCTION TEST PART
2
Exchange the FRU group 25
189
MOSS PROCESSOR INSTRUCTION TEST PART 2
NOT OK
18A
MOSS PROCESSOR INSTRUCTION TEST PART 2
SUCCESSFULLY RUN Progression code.
If permanently displayed, exchange
the FRU group 25
18B Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
18C CONTROL LOST DURING TOD ADAPTER TEST Exchange the FRU group 6
18D
END OF TOD TEST (SUCCESSFUL OR NOT)
Progression code.
If permanently displayed, exchange
the FRU group 2
18E to 18F Unused
Go to “MAP 3220: Undefined Panel
Message” on page 2-5
190 START OF MCC TEST Progression code.
If permanently displayed, exchange
the FRU group 9
191
HARDWIRED CONDITIONS IMPOSSIBLE TO GET IN
PCA 1
Exchange the FRU group 5
192 ERROR IN PCA 1 TEST ASYNCHRONOUS Exchange the FRU group 26
193
UNEXPECTED LEVEL 0 INTERRUPT DURING PCA1
TEST
Exchange the FRU group 5
194
ERROR IN PCA 1 INTERNAL WRAP ASYNCHRO-
NOUS TEST.
Exchange the FRU group 26
195
UNEXPECTED LEVEL 0 INTERRUPT DURING PCA1
TEST
Exchange the FRU group 6
196
HARDWIRED CONDITIONS IMPOSSIBLE TO GET IN
PCA 2
Exchange the FRU group 5
197 ERROR IN PCA 2 TEST ASYNCHRONOUS Exchange the FRU group 26
198 UNEXPECTED LEVEL 0 INT. DURING PCA2 TEST Exchange the FRU group 5
199
ERROR IN PCA 2 INTERNAL WRAP ASYNCHRO-
NOUS TEST.
Exchange the FRU group 26
19A UNEXPECTED INT. (<> LEVEL 0) IN PCA2 TEST Exchange the FRU group 6
19B
HARDWIRED CONDITIONS IMPOSSIBLE TO GET IN
PCA 3
Exchange the FRU group 5
19C ERROR IN PCA 3 TEST SYNCHRONOUS Exchange the FRU group 26
19D UNEXPECTED LEVEL 0 INT. DURING PCA3 TEST Exchange the FRU group 5
19E
ERROR IN PCA 3 INTERNAL WRAP SYNCHRONOUS
TEST.
Exchange the FRU group 26
19F UNEXPECTED INT. (<> LEVEL 0) IN PCA3 TEST Exchange the FRU group 5
1A0
WRAP BLOCK DOES NOT SEEM TO BE PRESENT
ON LOCAL PORT , OR SIGNALS TESTED ARE NOT
OK.
Exchange the FRU group 27
1A1
LOCAL CONSOLE CABLE DOWN (WHEN WRAP
BLOCK INSTALLED)
Exchange the FRU group 28
1A2 LOCAL CONSOLE PCA ERROR Exchange the FRU group 26
1A3
WRAP BLOCK DOES NOT SEEM TO BE PRESENT
ON REMOTE PORT , OR SIGNALS TESTED ARE
NOT OK.
Exchange the FRU group 27
1-24 3745 Models 130 to 17A: MIP