IBM ibm Home Theater Server User Manual


 
CE leaving procedure
10. Replace all covers and close the doors.
11. Leave the machine in a safe condition.
12. Record the actions taken and the FRUs replaced during the call.
If the origin of the intervention was an alarm A5, report it as preventive maintenance (Service Code
08).
13. Update the PMH record for this call.
14. Return parts to the stock room.
Had the whole configuration Ask the customer to IPL and load the NCP into the CCU.
Verify that IPL completes whithout errors.
If the system is not available to load the NCP into the
CCU, return the console to maintenance mode and IPL
the CCU, one step at a time. At the beginning of phase 4
(IPL stop with phase 4 displayed) , verify that the
message 'SCANNER(s) not IMLED xxxx' is not displayed.
Continue to end of phase 4.
Disabled some channels Ask the customer to:
Re-enable the channels using the CID screen.
Put the channels online from the host.
Put the 3746-900 Offline Put the 3746-900 to online mode.
Been working on the 3746-900 in con-
current maintenance mode on
processors or couplers.
Use the CDF-E display function to check that the
replaced/tested FRUs are available or active.
4-104 3745 Models 130 to 17A: MIP