IBM ibm Home Theater Server User Manual


 
3745 Panel Codes
Table 1-5 (Page 20 of 33). Panel Codes. An
following a panel code denotes that the code should 'Blink'.
Panel
Code
Definition
Action: Go to “3745 FRU Group
Table” on page 1-49
or to MAP number
B9E Ring lobe wire fault at open
Check the LAN cable connections, if
the problem persists: Exchange the
FRU group 55.
B9F Remote station connection time out
Check that the service processor is
powered On, if yes: there was a LAN
time out or a LAN problem or a
service processor problem is sus-
pected. Go to
Service Processor
Installation and Maintenance
manual,
chapter "Service Processor Problem
Determination".
BB0 Ring link lost
Communication lost between MOSS
and MOSS-E.
Check the physical connection
between the 3745 and the service
processor.
Check that the service processor
is powered ON.
Review the configuration of
stations connected to the LAN.
The MOSS-to-MOSS-E con-
nection will be automatically
recovered when the number of
broadcast frames goes under 200
per second.
If the problem continues a Service
Processor problem is suspected, go
to
Service Processor Installation and
Maintenance
manual, chapter
"Service Processor Problem Determi-
nation" or a MOSS microcode
problem is suspected. Contact your
support structure, refer to “Contacting
Support” on page A-1.
BB1 Ring DM/DISC received/acked A Service Processor problem is sus-
pected, go to
Service Processor
Installation and Maintenance
manual,
chapter "Service Processor Problem
Determination" or a MOSS microcode
problem is suspected. Contact your
support structure, refer to “Contacting
Support” on page A-1.
BB2 Ring FRMR received
BB3 Ring SABME received
BB4 Ring TI timer expired
BB5 Ring FRMR sent
BB6 Ring unexpected SABME received
BC0 Permanent ring beaconing
A LAN ring problem is suspected.
Use the
Token-Ring Network,
Problem Determination Guide
SX27-3710.
BC1 Ring lobe wire fault
Check the LAN cable connections, if
the problem persists: Exchange the
FRU group 55.
BC2 Auto removal while beaconing Exchange the FRU group 55.
BC3 Ring remove received
A LAN problem is suspected. Use
the
Token-Ring Network, Problem
Determination Guide
SX27-3710.
BC4 Ring auto removal
Check the LAN cable connections, if
the problem persists: Exchange the
FRU group 55.
BD0 FSM time out A Service Processor problem is sus-
pected. Go to
Service Processor
Installation and Maintenance
manual,
chapter "Service Processor Problem
Determination".
BE0 Watchdog time out
1-34 3745 Models 130 to 17A: MIP