RoboteQ AX2550/2850 TV Converter Box User Manual


 
AX2500/2850 Motor Controller Users Manual 157
Programmable Parameters List
This table shows only the parameters that can be programmed using the switches
and display. Other less commonly used parameters exist and are only accessible and pro-
grammable using the Configuration Utility (page 159) or the RS232 commands (page 99).
TABLE 27. Parameters accessible using the controller’s switches and display
Order Letter Description Possible Values (default)
See
pages
1 I Input Command
mode:
(0) = R/C Radio mode (default)
1 = RS232 full duplex, no watchdog
2 = RS232 half duplex, with watchdog
3 = Analog mode
page 69
page 87
page 107
2 C Motor Control mode (0) = Separate A, B, speed control, open
loop (default)
1 = Mixed A & B, speed control, open loop
For safety reasons, the modes below
cannot be selected using the switches.
2 = Speed control on A, open loop. Posi-
tion control on B
3 = A & B Position control
4 = Separate A, B, speed control, closed
loop
5 = Mixed A & B, speed control, closed
loop
6 = Speed control on A, closed loop. Posi-
tion control on B
page 36
3AAmp limit 0 = 30A
1 = 45A
2 = 60A
3 = 75A
4 = 90A
(5) = 105A default
6 = 120A
Amps may be set with a finer resolution
using the PC utility
page 38
4 S Acceleration 0 = very slow
1 = slow
(2) = medium (default)
3 = medium
4 = fast
5 = fastest
Acceleration may be set with a finer resolu-
tion using the PC utility
page 40