R/C Operation
84 AX2500/2850 Motor Controller Users Manual Version 1.7. February 1, 2005
Data Logging in R/C Mode
While in R/C Mode, the AX2500/2850 will continuously send a string of characters on the
RS232 output line. This string will contain 12 two-digits hexadecimal number representing
the 12 following operating parameters.
Captured R/C Command 1 and 2
Power Applied to Controllers output stage
Values applied to Analog inputs 1 and 2
Amps on channel 1 and 2
Internal Heat Sink temperatures 1 and 2
Main Battery voltage
Internal 12V voltage
Encoder Speed or Position feedback, if encoder module is present.
The entire string is repeated every 200 milliseconds with the latest internal parameter val-
ues. This information can be logged using the Roborun Utility (see Viewing and Logging
Data in Analog and R/C Modes on page 172). It may also be stored in a PDA that can be
placed in the mobile robot.
The string and data format is described in Analog and R/C Modes Data Logging String For-
mat on page 102. The serial ports output can be safely ignored if it is not required in the
application.
To read the output string while operating the controller with the R/C radio, you must mod-
ify the R/C cable to add an RS232 output wire and connector that will be connected to the
PCs communication port. Figure 55 and Figure 55 below shows the wiring diagram of the
modified R/C cable for connection to a PC or to a PDA, respectively.
Output C
ON
Output C
OFF
Toggle
Output D
No Change
Output D
FIGURE 54. Using Channel 3 to activate accessory outputs