RoboteQ AX2550/2850 TV Converter Box User Manual


 
Using the Roborun Configuration Utility
168 AX2500/2850 Motor Controller Users Manual Version 1.7. February 1, 2005
1- Run/Stop Button
This button will cause the PC to send the run commands to the controller and will update
the screen with measurements received from the controller.
When the program is running, the buttons caption changes to Stop. Pressing it again will
stop the motors and halt the exchange of data between the PC and the controller.
If you select another tab while the program is running, the program will stop as if the Stop
button was pressed.
2- Motor Power setting
This sub-frame contains a slider and several buttons. Moving the slider in any direction
away from the middle (stop) position will cause a power command to be issued to the con-
troller. The value of the command is shown in the text field below the slider.
The stop button will cause the slider to return to the middle (stop) position and a 0-value
command to be sent to the controller. The + and ++ buttons will cause the slider to move
by 1 or 10 power positions respectively.
3- Measurement
These series of fields display the various operating parameters reported in real-time by the
controller:
The Amps field reports the current measured at each channel. The Peak Amps field will
store the highest measured Amp value from the moment the program began or from
when the peak was reset using the Clr Peak button.
1
2
3
FIGURE 99. Motor exercising and monitoring screen
4
6
5
7
8