RoboteQ AX2550/2850 TV Converter Box User Manual


 
Using the Roborun Configuration Utility
174 AX2500/2850 Motor Controller Users Manual Version 1.7. February 1, 2005
Updating the Controllers Software
The AX2500/2850s operating software can be easily upgraded after it has left the factory.
This feature makes it possible to add new features and enhance existing ones from time to
time.
Important Warning
Updating the controller will cause all its parameters to reset to their default condi-
tions. You should re-enter these parameters to your desired value prior to re-install-
ing and using the controller.
The upgrade procedure is quick, easy and error proof:
1- Connect the controller to the PC via the provided RS232 cable.
2- Apply a 12V to 40V power supply to the controllers Ground and Power Control input
(thin black and yellow wires).
3- Launch the Roborun utility if it is not already running. Then click on the Update Con-
troller Software button.
4- If the controller is On, Roborun will find it and prompt you to select the new software
file. It may happen that the controller is not responding properly and you may be asked
to reset it while connected.
5- Press the Program button to start programming. Do not interrupt or cut the
power to the controller while the new program is loading into Flash memory.
6- After a verification, you will be notified that the operation was successful and you will
see the new software revision and date as reported by the controller.
Notes:
The Updating utility will automatically detect whether the new software is intended for the
main or encoders MCU and program one or the other accordingly.
It is a good idea to load the controllers parameters into the PC and save them to disk prior
to updating the software. After the new software in transferred to the controller, you can
use the Load Parameters from Disk function and transfer them to the controller using
the Save to Controller button.
Creating Customized Object Files
It is possible to create versions of the controllers firmware with default settings that are
different than those chosen by Roboteq. This capability can be used to improve system reli-
ability in the unlikely, but not impossible occurrence of a parameter loss in the controllers
non-volatile memory. Should such an event occur, the controller would revert to the
defaults required by the application.