5.3 Serial Communication
5.3.7 CSET instruction (receive data clear)
5-83
ZP_CSET
5
MODULE DEDICATED
INSTRUCTION
ZP_CSET
Control Data
Program Example
The following program clears the receive data in the Q series C24 side.
(For the Q series C24 whose I/O signals are X/Y00 to X/Y1F)
[Structured ladder/FBD]
Device Item Setting data Setting range Setting side
[0]
Execution type Specify '0'.
0User
[1]
Completion status
The instruction completion status is stored.
0 : Normal completion
Other than 0 :
Error completion (error code)
System
[2]
Request type
Specify the request.
4: Receive data clear request
4User
[3]
For system
––Systemto
[111]
s2
s2
s2
s2
s2
Clears execution
type to 0
Sets request type
Clears data
Turns normal completion
flag ON
Turns error completion
flag ON
Stores error code
Turns normal completion
flag OFF
Turns error completion
flag OFF