Mitsubishi Electronics MELSEC Q series MELSEC L series Home Theater Server User Manual


 
5-10
5.1 Analog Instruction
5.1.2 OGLOAD instruction
G_OGLOAD
(5) Q68AD-G
*1
Device Item Setting data Setting range Setting side
[0]
System area
[1]
Completion status
The instruction completion status is stored.
0 :Normal completion
Other than 0 :Error completion (error code)
System
[2]
Pass data classification setting
Specify the voltage/current of the offset/gain values to
be read.
0: Voltage specified
1: Current specified
0000
H to
00FF
H
User
[3]
System area
––
[4]
CH1 Industrial shipment settings offset value
System
[5]
CH1 Industrial shipment settings gain value
––
System
[6]
CH2 Industrial shipment settings offset value
System
[7]
CH2 Industrial shipment settings gain value
––
System
[8]
CH3 Industrial shipment settings offset value
––
System
[9]
CH3 Industrial shipment settings gain value
––
System
[10]
CH4 Industrial shipment settings offset value
––
System
[11]
CH4 Industrial shipment settings gain value
––
System
[12]
CH5 Industrial shipment settings offset value
––
System
[13]
CH5 Industrial shipment settings gain value
––
System
[14]
CH6 Industrial shipment settings offset value
––
System
[15]
CH6 Industrial shipment settings gain value
––
System
[16]
CH7 Industrial shipment settings offset value
––
System
[17]
CH7 Industrial shipment settings gain value
––
System
[18]
CH8 Industrial shipment settings offset value
––
System
[19]
CH8 Industrial shipment settings gain value
––
System
[20]
CH1 User range settings offset value
––
System
[21]
CH1 User range settings gain value
––
System
[22]
CH2 User range settings offset value
––
System
[23]
CH2 User range settings gain value
––
System
[24]
CH3 User range settings offset value
––
System
[25]
CH3 User range settings gain value
––
System
[26]
CH4 User range settings offset value
––
System
[27]
CH4 User range settings gain value
––
System
[28]
CH5 User range settings offset value
––
System
[29]
CH5 User range settings gain value
––
System
[30]
CH6 User range settings offset value
––
System
[31]
CH6 User range settings gain value
––
System
[32]
CH7 User range settings offset value
––
System
[33]
CH7 User range settings gain value
––
System
[34]
CH8 User range settings offset value
––
System
[35]
CH8 User range settings gain value
––
System
*1 : Set the data only to the Pass data classification setting [2].
When the data is written to the area to be set by system, offset/gain setting value is not read properly.
s
s
s
0
0
CH4
CH3CH2CH1
b15 b8 b3 b2 b1 b0
CH8CH7CH6CH5
b7 b6 b5 b4
to
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s