7.7 SOCCSET Instruction
SP_SOCCSET
Control Data
Precautions
(1) Use the Built-in Ethernet port QCPU of which the function version is B or later and the first
five digits of the serial number are '11012' or higher.
(2) Use the LCPU other than L02SCPU and L02SCPU-P.
Device Item Setting data Setting range Setting side
[0]
System area

[1]
Completion status
The instruction application status is stored.
0 : Normal completion
Other than 0 : Error completion (error code)
System
[2]
[3]
Destination IP address Specify the IP address of the external device.
1H to
FFFFFFFF
H
0H : No
destination
(FFFFFFFF
H :
broadcast)
User
[4]
Destination port No. Specify the port number of the external device.
1H to FFFFH
(FFFFH:
broadcast)
User
s2
s2
s2