5.1 Analog Instruction
5.1.2 OGLOAD instruction
5-17
5
MODULE DEDICATED
INSTRUCTION
G_OGLOAD
G_OGLOAD
Control data of Q64RD/Q64RD-G (3/5)
Device Item Setting data
Setting
range
Setting
side
Q64RD
-G
[40]
4-wire CH2 Factory default offset value (L)
––System
[41]
4-wire CH2 Factory default offset value (H)
[42]
4-wire CH2 Factory default gain value (L)
––System
[43]
4-wire CH2 Factory default gain value (H)
[44]
4-wire CH2 User range settings offset value (L)
––System
[45]
4-wire CH2 User range settings offset value (H)
[46]
4-wire CH2 User range settings gain value (L)
––System
[47]
4-wire CH2 User range settings gain value (H)
[48]
4-wire CH2 User range settings resistance offset value (L)
––System
[49]
4-wire CH2 User range settings resistance offset value (H)
[50]
4-wire CH2 User range settings resistance gain value (L)
––System
[51]
4-wire CH2 User range settings resistance gain value (H)
Q64RD
[52]
3-wire CH3 Factory default offset value
––System
[53]
3-wire CH3 Factory default offset value
––System
[54]
3-wire CH3 Factory default gain value
––System
[55]
3-wire CH3 Factory default gain value
––System
[56]
3-wire CH3 User range settings offset value
––System
[57]
3-wire CH3 User range settings offset value
––System
[58]
3-wire CH3 User range settings gain value
––System
[59]
3-wire CH3 User range settings gain value
––System
Q64RD
-G
[52]
3-wire CH3 Factory default offset value (L)
––System
[53]
3-wire CH3 Factory default offset value (H)
[54]
3-wire CH3 Factory default gain value (L)
––System
[55]
3-wire CH3 Factory default gain value (H)
[56]
3-wire CH3 User range settings offset value (L)
––System
[57]
3-wire CH3 User range settings offset value (H)
[58]
3-wire CH3 User range settings gain value (L)
––System
[59]
3-wire CH3 User range settings gain value (H)
[60]
3-wire CH3 User range settings resistance offset value (L)
––System
[61]
3-wire CH3 User range settings resistance offset value (H)
[62]
3-wire CH3 User range settings resistance gain value (L)
––System
[63]
3-wire CH3 User range settings resistance gain value (H)
Q64RD
[64]
4-wire CH3 Factory default offset value
––System
[65]
4-wire CH3 Factory default offset value
––System
[66]
4-wire CH3 Factory default gain value
––System
[67]
4-wire CH3 Factory default gain value
––System
[68]
4-wire CH3 User range settings offset value
––System
[69]
4-wire CH3 User range settings offset value
––System
[70]
4-wire CH3 User range settings gain value
––System
[71]
4-wire CH3 User range settings gain value
––System