5.3 Serial Communication
5.3.11 CSET instruction (programmable controller CPU monitor)
ZP_CSET
Control Data
(1) Registering the programmable controller CPU monitoring
Device Item Setting data Setting range Setting side
[0]
Execution type Specify '0'.
0User
[1]
Completion status
The instruction completion status is stored.
0 : Normal completion
Other than 0 :
Error completion (error code)
System
[2]
Request type
Specify the request.
2: Registration of programmable controller CPU
monitoring
2
User
[3]
Cycle time unit
Specify the unit of cycle time.
0: 100ms 1: Second 2: Minute
0 to 2
User
[4]
Cycle time
Specify the cycle time.
1H to FFFFH: Cycle time
1
H to FFFFH
User
[5]
Programmable controller CPU monitoring
function
Specify the monitoring function.
1: Constant cycle transmission
2: Condition agreement transmission
1,2
User
[6]
Programmable controller CPU monitoring
transmission method
Specify the transmission method.
0: Data transmission (device data, CPU error
information)
1: Notification
0,1
User
[7]
Constant cycle transmission
User frame output start pointer
Specify the start pointer of the table to which the user
frame number for constant cycle transmission is set.
0 : No specification (at condition
agreement transmission and
notification)
1 to 100 : Start pointer
0, 1 to 100
User
[8]
Number of user frame transmissions
Specify the number of user frame transmissions
(outputs) for constant cycle transmission.
0 : No specification (at condition
agreement transmission and
notification)
1 to 100 : Number of transmissions
0, 1 to 100
User
[9]
Modem connection data No.
Specify the data number for modem function
connection when making notification in constant cycle
transmission.
0 : No specification (at data
transmission and condition
agreement transmission)
BB8
H to BD5H : Connection data number (flash
ROM)
8001
H to 801FH: Connection data number
(buffer memory)
0,
BB8
H to
BD5
H,
8001
H to
801F
H
User
[10]
Number of registered word blocks
Specify the number of blocks of the word device to be
monitored.
0 to 10
User
[11]
Number of registered bit blocks
Specify the number of blocks of the bit device to be
monitored.
0 to 10
User
[12]
Programmable controller CPU error
monitoring
(programmable controller CPU status
monitoring)
Specify whether to also execute programmable
controller CPU error monitoring.
0: Not monitored 1: Monitored
0,1
User
s2
s2
s2
s2
s2
s2
s2
s2
s2
s2
s2
s2
s2