5.4 Network Dedicated Instruction
5.4.10 WRITE instruction
J_WRITE, G_WRITE
*1 : Specification is possible when the host station is a network module or Ethernet module of function
version D or later.
(Specification is not possible for other modules. An access is always made to the target station CPU.)
*2 : Specification is possible when the versions of the QCPU and the network module on the host station and
the target station are as indicated below.
(Specification is not possible for other modules. An access is always made to the target station CPU.)
Network module: The first five digits of the serial number are '06092' or higher.
QCPU: The first five digits of the serial number are '06092' or higher.
*3 : Data are stored only when 1 is set in bit 7 of Error completion type ( [0]).
[8]
Arrival monitoring time
Specify the monitoring time required for instruction completion. (Setting
is available when Execution type is set to '1: With arrival confirmation' in
[0].)
If the instruction is not completed within this time, it is resent by the
number of times specified in [7].
0 to 32767 User
[9]
Write data length
Specify the number of write data.
1 to 8192 User
[10]
(Reserved)
––
[11]
Clock set flag
*3
Valid/invalid status of the data in the area starting from [12] is stored.
0: Invalid
1: Valid
System
[12]
to
[15]
Clock data at the time of
error completion
*3
Clock data at the time of error completion are stored in BCD format.
System
[16]
Error-detected network No.
*3
Network number of the station where an error was detected is stored.
(However, when an error was detected at the host station, the network
number is not stored.)
1 to 239: Network number
System
[17]
Error-detected station No.
*3
Number of the station where an error was detected is stored.
(However, when an error was detected at the host station, the network
number is not stored.)
System
Device Item Setting data Setting range Setting side
s1
s1
s1
Description Setting value
Ethernet
0 to TCP retransmission
timer value: Monitoring is
performed by the TCP
retransmission timer value.
(TCP retransmission timer
value + 1) to 16383:
Monitoring time (unit:
second)
0 to 16383
MELSECNET/H
CC-Link IE
0: 10 seconds
1 to 32767: 1 to 32767
seconds
0 to 32767
s1
Description Setting value
Ethernet
MELSECNET/H
CC-Link IE Field Network
1 to 960
(word)
CC-Link IE Controller Network
1 to 8192
(word)
s1
s1
s1
s1
s1
[12 ]
[13 ]
[14 ]
[15 ]
b15 b8 b7to b0to
s1
s1
s1
s1
Month (01H to 12H)
Hour (00
H to 23H)
Second (00
H to 59H)
Year (00
H
to 99
H
) First two digits
Year (00
H
to 99
H
) Last two digits
Day (01
H
to 31
H
)
Minute (00H to 59H)
Day of week (00
H
to 06
H
)
00
H
(Sun.) to 06
H
(Sat.)
s1
s1
Setting value Description
MELSECNET/H 1 to 64
Ethernet
CC-Link IE Controller Network
1 to 120
CC-Link IE Field Network -
Master station 125 (7DH)
Local station or the intelligent device
station
1 to 120
s1