Mitsubishi Electronics MELSEC Q series MELSEC L series Home Theater Server User Manual


 
5-18
5.1 Analog Instruction
5.1.2 OGLOAD instruction
G_OGLOAD
Control data of Q64RD/Q64RD-G (4/5)
Device Item Setting data
Setting
range
Setting
side
Q64RD
-G
[64]
4-wire CH3 Factory default offset value (L)
––System
[65]
4-wire CH3 Factory default offset value (H)
[66]
4-wire CH3 Factory default gain value (L)
––System
[67]
4-wire CH3 Factory default gain value (H)
[68]
4-wire CH3 User range settings offset value (L)
––System
[69]
4-wire CH3 User range settings offset value (H)
[70]
4-wire CH3 User range settings gain value (L)
––System
[71]
4-wire CH3 User range settings gain value (H)
[72]
4-wire CH3 User range settings resistance offset value (L)
––System
[73]
4-wire CH3 User range settings resistance offset value (H)
[74]
4-wire CH3 User range settings resistance gain value (L)
––System
[75]
4-wire CH3 User range settings resistance gain value (H)
Q64RD
[76]
3-wire CH4 Factory default offset value
––System
[77]
3-wire CH4 Factory default offset value
––System
[78]
3-wire CH4 Factory default gain value
––System
[79]
3-wire CH4 Factory default gain value
––System
[80]
3-wire CH4 User range settings offset value
––System
[81]
3-wire CH4 User range settings offset value
––System
[82]
3-wire CH4 User range settings gain value
––System
[83]
3-wire CH4 User range settings gain value
––System
Q64RD
-G
[76]
3-wire CH4 Factory default offset value (L)
––System
[77]
3-wire CH4 Factory default offset value (H)
[78]
3-wire CH4 Factory default gain value (L)
––System
[79]
3-wire CH4 Factory default gain value (H)
[80]
3-wire CH4 User range settings offset value (L)
––System
[81]
3-wire CH4 User range settings offset value (H)
[82]
3-wire CH4 User range settings gain value (L)
––System
[83]
3-wire CH4 User range settings gain value (H)
[84]
3-wire CH4 User range settings resistance offset value (L)
––System
[85]
3-wire CH4 User range settings resistance offset value (H)
[86]
3-wire CH4 User range settings resistance gain value (L)
––System
[87]
3-wire CH4 User range settings resistance gain value (H)
Q64RD
[88]
4-wire CH4 Factory default offset value
––System
[89]
4-wire CH4 Factory default offset value
––System
[90]
4-wire CH4 Factory default gain value
––System
[91]
4-wire CH4 Factory default gain value
––System
[92]
4-wire CH4 User range settings offset value
––System
[93]
4-wire CH4 User range settings offset value
––System
[94]
4-wire CH4 User range settings gain value
––System
[95]
4-wire CH4 User range settings gain value