5.4 Network Dedicated Instruction
5.4.32 UINI instruction
5-243
Z_UINI
5
MODULE DEDICATED
INSTRUCTION
Z_UINI
5.4.32 UINI instruction
Z_UINI
*1: Local devices and file registers per program cannot be used as setting data.
Function
Ethernet: This instruction reinitializes the Ethernet module.
CC-Link IE Controller Network: For Universal model QCPU, this instruction sets the station
number of the CC-Link IE Controller Network module on normal station (host station).
*1: ZP_UINI instruction only
Z(P)_UINI
P: Executing condition
:
indicates any of the following
instructions.
Z_UINI ZP_UINI
Input argument EN:
Executing condition :Bit
Un*:
Start I/O number of the module
(00 to FE: Higher two digits when expressing the I/O number in
three digits)
:String
s:
Variable that stores control data :Array of ANY16 [0..9]
Output argument ENO:
Execution result :Bit
d:
Variable that turns ON upon completion of the instruction
d[1] also turns ON at the time of error completion.
:Array of bit [0..1]
Setting
data
*1
Internal device
R, ZR
J\
U\G
Zn
Constant
Others
Bit Word Bit Word

CC IE C
Ether
Z_UINI
EN ENO
Un* d
s
Z_UINI
(EN, Un*, s, d);ENO:=
Structured ladder/FBD ST
s
d