5.1 Analog Instruction
5.1.3 OGSTOR instruction
5-37
5
MODULE DEDICATED
INSTRUCTION
G_OGSTOR
G_OGSTOR
(8) Q62DA-FG
Device Item Setting data Setting range Setting side
[0]
System area
––
[1]
Completion status
The instruction completion status is stored.
0 : Normal completion
Other than 0 :
Error completion (error code)
System
[2]
Pass data classification setting
The value set for pass data classification setting [2]
by the OGLOAD instruction is stored.
0H: User range setting 1 specified
1H: User range setting 2 specified
2H: User range setting 3 specified
System
[3]
System area
––
[4]
CH1 Industrial shipment settings offset value
(used for D/A)
––System
[5]
CH1 Industrial shipment settings gain value
(used for D/A)
––System
[6]
CH2 Industrial shipment settings offset value
(used for D/A)
––System
[7]
CH2 Industrial shipment settings gain value
(used for D/A)
––System
[8]
CH1 Industrial shipment settings offset value
(used for monitor output)
––System
[9]
CH1 Industrial shipment settings gain value
(used for monitor output)
––System
[10]
CH2 Industrial shipment settings offset value
(used for monitor output)
––System
[11]
CH2 Industrial shipment settings gain value
(used for monitor output)
––System
[12]
CH1 User range settings offset value (used
for D/A)
––System
[13]
CH1 User range settings gain value (used for
D/A)
––System
[14]
CH2 User range settings offset value (used
for D/A)
––System
[15]
CH2 User range settings gain value (used for
D/A)
––System
[16]
CH1 User range settings offset value (used
for monitor output)
––System
[17]
CH1 User range settings gain value (used for
monitor output)
––System
[18]
CH2 User range settings offset value (used
for monitor output)
––System
[19]
CH2 User range settings gain value (used for
monitor output)
––System
s
s
s
s
CH2 CH1
b15 to b12 b11 to b8 b7 to b4 b3 to b0
0H 0H
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s