Control Data
Device Item Setting data Setting range Setting side
[0]
Completion type
0User
[1]
Completion status
The instruction completion status is stored.
0 : Normal completion
Other than 0 : Error completion (error code)
System
[2]
Host station channel
Specify the channel of host station that stores receive data.
1 to 8 User
[3]
Channel used by sending
station
Channel used by the sending station is stored.
1 to 8: Channel
System
[4]
Network No. of sending
station
Network number of the sending station is stored.
1 to 239: Network number
System
[5]
Sending station No.
Station number of the sending station is stored.
System
[6]
System area
––
[7]
[8]
[9]
Receive data length
The number of received data stored in to + n is stored.
0 : No receive data
1 to 960 : Number of words of receive data
System
[10]
to
[17]
System area
––
s
b15 to b0
0 (Fixed)
s
s
Description Setting value
MELSECNET/H
Ethernet
CC-Link IE Controller Network
1 to 8
CC-Link IE Field Network 1 to 2
s
s
s
Setting value Description
MELSECNET/H 1 to 64
Ethernet
CC-Link IE Controller Network
1 to 120
CC-Link IE Field Network -
Master station 125 (7DH)
slave station 1 to 120
s
s
s
s
d1
d1
s
s