Mitsubishi Electronics -NZ2GF2B-60DA4 Universal Remote User Manual


 
106
(8) Response time
The following describes the response time until Trigger output completed flag (RX19) turns on after the trigger
output is requested.
(a) When Trigger output request (RY19) is assigned to Remote input (RX) using the
external signal assignment function
(Response time of the D/A converter module)
*1
+ (Response time of the extension input module)
*2
[ms]
*1 The response time of the D/A converter module is calculated as shown below.
(Number of the channels for which D/A conversion is enabled) × 0.1 [ms]
*2 The response time of the extension input module is the minimum time period until the D/A converter module recognizes
an input from the extension input module. The response time of the extension input module is calculated as shown
below.
(Input response time setting) + 0.5 [ms]
(b) When Trigger output request (RY19) is not assigned to Remote input (RX) using the
external signal assignment function
SM
*1
+ LS
*2
+ (Response time of the D/A converter module)
*3
[ms]
*1 SM: Sequence scan time [ms] ( User's manual for the CPU module used in the master station)
*2 LS: Link scan time [ms] ( User's manual for the master/local module used)
*3 The response time of the D/A converter module is calculated as shown below.
(Number of the channels for which D/A conversion is enabled) × 0.1 [ms]
(9) Input interval and the ON and OFF time of the trigger output request
When turning on Trigger output request, turn on or off Trigger output request satisfying the reference values of
the following items.
(a) When Trigger output request (RY19) is assigned to Remote input (RX) using the
external signal assignment function
The following table lists the input interval, ON time, and OFF time of Remote input (RX) to which Trigger output
request (RY19) is assigned.
*1 The response time of the extension input module is the minimum time period until the D/A converter module recognizes
an input from the extension input module. The response time of the extension input module is calculated as shown
below.
(Input response time setting) + 0.5 [ms]
Item Reference value
Input interval of the trigger
output request
(Response time of the extension input module)
*1
[ms] or longer
ON time of the trigger
output request
OFF time of the trigger
output request