187
APPENDICES
A
Appendix 9 Addition and Change of Functions
Appendix 9.1 Additional function
Appendix 9 Addition and Change of Functions
Appendix 9.1 Additional function
The following table lists the function added to the D/A converter module and GX Works2 and the serial number and
software version of the products that support the additional function.
Appendix 9.2 Change of function
The following table lists the changed functions of the D/A converter module and the operation differences between the
modules with different serial numbers.
Additional function
Serial number (first five
digits) of D/A converter
module
Version of GX Works2 Reference
Mode switch 15102 or later Version 1.501X or later Page 78, Section 8.2
Trigger output function 15102 or later Version 1.501X or later Page 101, Section 8.12
CC-Link IE Field Network
synchronous communication
function
15102 or later Version 1.501X or later Page 109, Section 8.13
Changed function
Serial number (first five digits)
is 15101 or earlier
Serial number (first five digits) is
15102 or later
Reference
Analog output
After power-on, the offset value is
output if communications to the master
station are not established and D/A
conversion is enabled.
After power-on, 0V/0mA is output if
communications to the master station are
not established and D/A conversion is
enabled.
Page 80,
Section 8.3
External signal assignment function
After power-on, the external signal
assignment function starts operating
even if communications to the master
station are not established.
After power-on, the external signal
assignment function does not operate until
communications to the master station are
established.
Page 118,
Section 8.15
(3)
REMFR/REMTO instruction
The REMFR/REMTO instruction is
accepted even if the network
parameter written to the CPU module
is not correct.
The REMFR/REMTO instruction is not
accepted if the network parameter written to
the CPU module is not correct.
Incorrect network parameter access error
occurs (minor error, 0150
H
).
Following operations on the "CC IE
Field Configuration" window
• [CC IE Field configuration] [Online]
[Parameter Processing of Slave
Station]
• [CC IE Field configuration] [Online]
[Command Execution of Slave
Station]
"Parameter Processing of Slave
Station" or "Command Execution of
Slave Station" is accepted even if the
network parameter written to the CPU
module is not correct.
"Parameter Processing of Slave Station" or
"Command Execution of Slave Station" is
not accepted if the network parameter
written to the CPU module is not correct.
Incorrect network parameter access error
occurs (minor error, 0150
H
).
Page 63,
Section 7.1