(3) Operation using the CC-Link IE Field Network synchronous communication
function
Every operation cycle of the simple motion module, the D/A conversion is performed for the D/A conversion
enabled channels.
Controlled by the D/A converter module
D/A conversion process
D/A
conversion
D/A
conversion
D/A
conversion
Digital value Digital value Digital valueDigital value
Operation cycle of the simple
motion module
CH Digital value
(RWw2 to RWw5)
D/A converts the received
digital value at one previous
operation cycle