APPENDICES
A
Appendix 3 Details of Remote Buffer Memory Areas
(2) Trigger output signal assignment (address: 0002
H
)
Assign Trigger output request (RY19) to Remote input (RX) of the extension input module using the external
signal assignment function. When assigned Remote input (RX) is turned on, the D/A converter module performs
the D/A conversion using the trigger output function.
(a) Setting range
Set the number for Remote input (RX) of the extension module, starting from the head number (0000
H
) of
Remote input (RX) of the main module.
Ex.
When Trigger output request (RY19) is assigned to 8
H
of Remote input (RX) starting from the head
number (0
H
) of the extension input module
Remote input (RX) of 8
H
from the head number of the extension input module corresponds to Remote
input (RX) of 28
H
from the head number of the main module.
Thus, set 28
H
for Trigger output signal assignment (address: 0002
H
).
(b) Enabling the setting
Turn on and off Initial data setting request flag (RY9).
(c) Default value
The default value is No assignment (FFFF
H
).
When a value out of the setting range is set, the error code (0170
H
) is stored in Latest error code (RWr0), Error flag
(RXA) turns on, and the ERR. LED turns on. The operation is performed in the previous setting.
When Remote input (RX) of the extension input module is set to Trigger output signal assignment (address: 0002
H
), the
D/A converter module does not perform the D/A conversion even if Trigger output request (RY19) is turned on. Turn on
Remote input (RX) which is set to Trigger output signal assignment (address: 0002
H
).
0H to to to1FH 20H 28H 2FH
to to0H 8H FH
Main module Extension module