27
CHAPTER 3 SPECIFICATIONS
3
3.3 Calculating Current Consumption
3.3 Calculating Current Consumption
The total current consumption of the modules is calculated by summing the module power supply current in the main
module and extension module.
The power supply current in the extension module should be within 30mA.
For the value of the module power supply current, refer to the specifications of each module.
• Performance Specifications of D/A converter module ( Page 25, Section 3.2)
• Performance Specifications of extension I/O module ( CC-Link IE Field Network Remote I/O Module
User's Manual)
The value of the module power supply current in the extension module described in the specifications is the value of
the module power supply current supplied from the main module.
D/A converter module Extension module
NZ2GF2B-60DA4
Module power supply current:
325mA
NZ2EX2B1-16T
Module power supply current:
30mA
355mA
(Total current consumption)
+=