3.7 List of Remote Buffer Memory
This section lists the remote buffer memory areas of the D/A converter module.
The remote buffer memory areas of the main module and extension module are assigned as shown below.
Ex.
Example of the remote buffer memory in the manual
For details on the remote buffer memory for the D/A converter module, refer to the following.
Page 162, Appendix 3
For details on the remote buffer memory of the connected extension module, refer to the following.
User's manual for the connected extension module
: Available, ×: Unavailable
Buffer memory address
Area Target
Access method
Decimal Hexadecimal
CC IE Field
configuration
of GX Works2
REMFR
instruction,
REMTO
instruction
*1
0 to 255
0000
H
to 00FF
H
Parameter area
Station-based parameter data
*2
256 to 511
0100
H
to 01FF
H
Module-based
parameter data
Main module
512 to 767
0200
H
to 02FF
H
Extension
module 1
768 to 1279
0300
H
to 04FF
H
System area
1280 to 1535
0500
H
to 05FF
H
Monitoring area
Station-based monitoring data
×
1536 to 1791
0600
H
to 06FF
H
Module-based
monitoring data
Main module
1792 to 2047
0700
H
to 07FF
H
Extension
module 1
2048 to 2559
0800
H
to 09FF
H
System area
2560 to 4095
0A00
H
to 0FFF
H
Error history area Station-based error history data
*2
4096 to 4351
1000
H
to 10FF
H
Module control data
area
Station-based control data
×
4352 to 4607
1100
H
to 11FF
H
Module-based
control data
Main module
4608 to 4863
1200
H
to 12FF
H
Extension
module 1
4864 to 5375
1300
H
to 14FF
H
System area
Main module Extension module 1
Setting item
D/A conversion enable/disable setting (address: 0102
H)
Address of a D/A converter module