HP (Hewlett-Packard) HP 16510B TV Converter Box User Manual


 
1 Insert Level To insert a level, touch the field labeled Insert Level. You will see the
following pop-up menu.
Cancel returns you to the sequence level pop-up without inserting a level.
Before inserts a level before the present level. After inserts a level after
the present level. If there are eight levels, the Insert Level field doesn’t
appear in the sequence level pop-ups.
2 Delete Level If you want to delete the present level, touch the field labeled Delete
Level. You will see a pop-up menu with the choices Cancel and Execute.
Cancel returns you to the sequence level pop-up without deleting the
level. Execute deletes the present level and returns you to the State Trace
Specification menu.
Note If there are only two levels, neither field can be deleted even though the
Delete Level field still appears in the menu. There will always be a trigger
term level and a store term level in Sequence Levels. Therefore, if you try
to delete either of these, all terms you have specified in these levels will be
set to default terms, and, the trigger and store term levels will remain.
Figure 5-55. Insert Level Pop-up Menu
Menus HP 16510B
5-48 Front-Panel Reference