HP (Hewlett-Packard) HP 16510B TV Converter Box User Manual


 
Measurement
and Display
Functions
Autoscale (Timing
Analyzer Only)
Autoscale searches for and displays channels with activity on the pods
assigned to the timing analyzer.
Acquisition
Specifications
Arming: Each analyzer can be armed by the run key, the other analyzer,
or the Intermodule Bus.
Trace Mode: Single mode acquires data once per trace specification;
repetitive mode repeats single mode acquisitions until stop is pressed or
until time interval between two specified patterns is less than or greater
than a specified value, or within or not within a specified range. There is
only one trace mode when two analyzers are on.
Labels Channels may be grouped together and given a six character name. Up to
20 labels in each analyzer may be assigned with up to 32 channels per
label. Primary use is for naming groups of channels such as address, data,
and control busses.
Indicators Activity Indicators: Provided in the Configuration, State Format, and
Timing Format menus for identifying high, low, or changing states on the
inputs.
Markers: Two markers (X and 0) are shown as dashed lines on the
display.
Trigger: Displayed as a vertical dashed line in the timing waveform
display and as line 0 in the state listing display.
HP 16510B Specifications and Operating Characteristics
Front-Panel Reference C-7