HP (Hewlett-Packard) HP 16510B TV Converter Box User Manual


 
The knob on the front panel is used to move the cursor on certain menus,
increment or decrement numeric fields, and to roll the display.
The touchscreen fields can be selected by touch or with the optional
mouse. To activate a touchscreen field by touch, touch or press the field
(the dark blue box) on the display with your finger until the field changes
color. Then remove your finger from the screen to activate your selection.
To activate a field with the optional mouse, position the cursor (+) of the
mouse over the desired field and press the button on the upper-left corner
of the mouse.
The user interfaces are discussed in more detail in the HP 16500A
Reference manual.
Configuration
Capabilities
The HP 16510B can be configured as two independent machines
(analyzers) maximum at one time or two machines interactively. The
combinations are:
Up to 80 channels state
Up to 80 channels timing
Two state machines with multiples of 16 channels per machine with
a combined maximum of 80 channels
One state and one timing machine with multiples of 16 channels per
machine with a combined maximum of 80 channels
* multiples of 16 channels
Figure 1-2. HP 16510B Configuration Capabilities
General Information HP 16510B
1 - 2 Front-panel Reference