6Clock The Clock field is present in the Format Specification menu only in the
state analyzer. This field displays the clocks that are to be used to clock
the logic analyzer. The display will be referred to as the "clocking
arrangement."
The HP 16510B Logic Analyzer has five clock channels, each of which is
on a pod. The clocks are connected through the pods simply for
convenience. The clock channels are labeled J, K, L, M, and N and are on
pods 1 through 5, respectively. The clocking of the state analyzer is
synchronous with your system because the analyzer uses the clocks
present in your system that assure valid data.
When you select the Clock field, you will see the following pop-up menu
with which you specify the clock.
You can use one of the clocks alone or combine them to build one
clocking arrangement.
If you select a field to the right of one of the clocks in the pop-up, you will
see another pop-up menu:
Figure 5-22. Clock Pop-up Menu