HP (Hewlett-Packard) HP 16510B TV Converter Box User Manual


 
Marker Functions Time Interval: The X and 0 markers measure the time interval between
one point on a timing waveform and trigger, two points on the same
timing waveform, two points on different waveforms, or two states (time
tagging on).
Delta States: (State Analyzer Only) The X and 0 markers measure the
number of tagged states between one state and trigger, or between two
states.
Patterns: TheXand0markerscanbeusedtolocatethenth occurrence of
a specified pattern before or after trigger, or after the beginning of data.
The 0 marker can also find the nth occurrence of a pattern before or after
the X marker.
Statistics: X to 0 marker statistics are calculated for repetitive
acquisitions. Patterns must be specified for both markers and statistics are
kept only when both patterns can be found in an acquisition. Statistics are
minimum X to 0 time, maximum X to 0 time, average X to 0 time, and
ratio of valid runs to total runs.
Run/Stop
Functions
Run: Starts acquisition of data in specified trace mode.
Stop: In single trace mode or the first run of a repetitive acquisition,
STOP halts acquisition and displays the current acquisition data. For
subsequent runs in repetitive mode, STOP halts acquisition of data and
does not change current display.
Data Display/Entry Display Modes: State listing; timing waveforms; interleaved,
time-correlated listing of two state analyzers (time tagging on);
time-correlated state listing and timing waveform display (state listing in
upper half, timing waveform in lower half, and time tagging on).
Timing Waveform: Pattern readout of timing waveforms at X or 0
marker.
Bases: Binary, Octal, Decimal, Hexadecimal, ASCII (display only), and
User-defined symbols.
Specifications and Operating Characteristics HP 16510B
C-8 Front-Panel Reference