Compare Range
The Compare Range function allows you to define a subset of the total
number of states in the compare image to be used in the comparison. The
range is specified by setting start and stop boundaries. Only bits in states
(lines) on or between the boundaries are compared against the acquired
data. This function can be accessed by selecting the "Compare
Full"/"Compare Partial" field in either the Compare or Difference listing
menus (see figure 9-3). When selected, a pop-up appears in which you
select either the "Full" or "Partial" option. When the "Partial" option is
selected, fields for setting the start state and stop state values appear.
Figure 9-3. Compare Full/Compare Partial Field
State Compare Menu HP 16510B
9-6 Front-Panel Reference