HP (Hewlett-Packard) HP 16510B TV Converter Box User Manual


 
C
Specifications and Characteristics
Introduction This appendix lists the specifications, operating characteristics, and
supplemental characteristics of the HP 16510B Logic Analyzer Module.
Specifications
Probes Minimum Swing: 600 mV peak-to-peak.
Threshold Accuracy:
Voltage Range Accuracy
2.0V to +2.0V 150 mV
9.9V to 2.1V 300 mV
+2.1V to +9.9V 300 mV
State Mode Clock Repetition Rate: Single phase is 35 MHz maximum. With time or
state counting, minimum time between states is 60 ns. Both mixed and
demultiplexed clocking use master-slave clock timing; master clock must
followslaveclockbyatleast10nsandprecedethenextslaveclockby>
50 ns.
Clock Pulse Width: 10 ns at threshold.
Setup Time: Data must be present prior to clock transition, 10 ns.
Hold Time: Data must be present after rising clock transition on all pods;
0 ns. Data must be present after falling clock transition on pods 1,3 and 5;
0 ns. Data must be present after falling clock transition on pods 2 and 4; 1
ns.
HP 16510B Specifications and Operating Characteristics
Front-Panel Reference C-1