HP (Hewlett-Packard) HP 16510B TV Converter Box User Manual


 
General Purpose
Probing
General purpose probing involves connecting the probes directly to your
target system without using the interface. General purpose probing does
not limit you to specific hook-up schemes as the probe interface does.
The Termination
Adapter
The optional termination adapter (HP Part No. 01650-63201) allows you
to connect the probe cables directly to test ports on your target system
without the probes. However, since the probes contain the proper
termination for the logic analyzer inputs, a termination must be provided
when you aren’t using the probes. The termination adapter provides this
termination.
The termination adapter is designed to connect to a 20 (2x10) position,
4-wall, low profile header connector, 3M
Series 3592 or equivalent.
You connect the termination adapter to the probe cable in place of the pod
connector and connect the other end of the adapter directly to your test
port.
Figure 2-2. Termination Adapter
HP 16510B Probing
Front-panel Reference 2 - 3