HP (Hewlett-Packard) HP 16510B TV Converter Box User Manual


 
The Time X to O field will change according to the position of the X and
O markers. It displays the total time between the states marked by the X
and O markers.
Markers Statistics When statistics are specified for markers, the logic analyzer will display
the:
Total runs
Number of valid runs (runs where markers were able to be placed on
specified patterns)
Minimum time between the X and O markers
Maximum time between the X and O markers
Average time between the X and O markers
How the statistics will be updated depends on the state trace mode (single
or repetitive).
In repetitive, statistics will be updated each time a valid run occurs until
you touch Stop. When you touch Run after Stop, the statistics will be
cleared and will restart from zero.
In single, each time you touch Run an additional valid run will be added to
the data and the statistics will be updated. This will continue unless you
change the placement of the X and O markers between runs.
Markers States When the Count is set to State in the State Trace Specification menu, you
have the option of placing the X and O markers on states of interest in the
listing and the logic analyzer will tell you:
Trig(ger) to X
Trig(ger) to O
XtoO(x)
This feature is similar to "Markers Time" except the number of states are
displayed instead of time.
HP 16510B Interpreting the Display
Front-Panel Reference 6 - 15