Mitsubishi Electronics FX5 Universal Remote User Manual


 
APPENDIX
Appendix 1 Special Relay List
229
A
SM4645 High-speed counter ring length (CH2) OFF: Disabled
ON: Enabled
R/W
SM4646 High-speed counter ring length (CH3) OFF: Disabled
ON: Enabled
R/W
SM4647 High-speed counter ring length (CH4) OFF: Disabled
ON: Enabled
R/W
SM4648 High-speed counter ring length (CH5) OFF: Disabled
ON: Enabled
R/W
SM4649 High-speed counter ring length (CH6) OFF: Disabled
ON: Enabled
R/W
SM4650 High-speed counter ring length (CH7) OFF: Disabled
ON: Enabled
R/W
SM4651 High-speed counter ring length (CH8) OFF: Disabled
ON: Enabled
R/W
SM4980 High-speed comparison table (high-speed compare
instruction) operation
OFF: Stopped
ON: Operation
R
SM4982 High-speed comparison table (high-speed compare
instruction) error
OFF: No error
ON: Error
R/W
SM5000 Multi-point output high-speed comparison table operation OFF: Stopped
ON: Operation
R
SM5001 Multi-point output high-speed comparison table
completion
OFF: Not completed
ON: Completion
R/W
SM5020 Pulse width measurement operation (CH1) OFF: Stopped
ON: Operation
R
SM5021 Pulse width measurement operation (CH2) OFF: Stopped
ON: Operation
R
SM5022 Pulse width measurement operation (CH3) OFF: Stopped
ON: Operation
R
SM5023 Pulse width measurement operation (CH4) OFF: Stopped
ON: Operation
R
SM5036 Pulse width measurement rising flag (CH1) OFF: Cycle measurement not completed
ON: Cycle measurement completion
R
SM5037 Pulse width measurement rising flag (CH2) OFF: Cycle measurement not completed
ON: Cycle measurement completion
R
SM5038 Pulse width measurement rising flag (CH3) OFF: Cycle measurement not completed
ON: Cycle measurement completion
R
SM5039 Pulse width measurement rising flag (CH4) OFF: Cycle measurement not completed
ON: Cycle measurement completion
R
SM5052 Pulse width measurement falling flag (CH1) OFF: Pulse width measurement not completed
ON: Pulse width measurement completion
R
SM5053 Pulse width measurement falling flag (CH2) OFF: Pulse width measurement not completed
ON: Pulse width measurement completion
R
SM5054 Pulse width measurement falling flag (CH3) OFF: Pulse width measurement not completed
ON: Pulse width measurement completion
R
SM5055 Pulse width measurement falling flag (CH4) OFF: Pulse width measurement not completed
ON: Pulse width measurement completion
R
SM5068 Pulse width measurement mode (CH1) OFF: Always measurement mode
ON: 1 time measurement mode
R/W
SM5069 Pulse width measurement mode (CH2) OFF: Always measurement mode
ON: 1 time measurement mode
R/W
SM5070 Pulse width measurement mode (CH3) OFF: Always measurement mode
ON: 1 time measurement mode
R/W
SM5071 Pulse width measurement mode (CH4) OFF: Always measurement mode
ON: 1 time measurement mode
R/W
SM5300 PWM function operation (CH1) OFF: Stopped
ON: Operation
R
SM5301 PWM function operation (CH2) OFF: Stopped
ON: Operation
R
SM5302 PWM function operation (CH3) OFF: Stopped
ON: Operation
R
No. Name Description R/W