Mitsubishi Electronics FX5 Universal Remote User Manual


 
11 REMOTE OPERATION
11.4 Relationship Between Remote Operation and CPU Module
91
11
11.4 Relationship Between Remote Operation and CPU
Module
Relationship between remote operation and RUN/STOP status of the CPU module
The following table shows operation status of the CPU module by the combination of remote operation and RUN/STOP status
of the CPU module.
*1 When executing by the RUN contact, setting of RUN contact is required in the CPU parameter.
*2 Remote reset setting is required in the CPU parameter.
*3 When a CPU module is changed to STOP status by a remote operation, remote reset is possible.
*4 Includes even the cases where CPU module has stopped due to an error.
Switch RUN/STOP status Remote operation
RUN
*1
STOP PAUSE RESET
*2
RUN RUN STOP PAUSE Operation not possible
*3
STOP STOP STOP STOP RESET
*4