Appendix 3 Error Code
3634H Axis 4 positioning
address error
The 32-bit range was exceeded when
the unit of the positioning address was
converted.
The total transfer distance before and
after the interrupt of the DVIT instruction
or 1-speed positioning with interruption
exceeded 7FFFFFFFH.
Pulses of 7FFFFFFFH or greater are
needed to specify an absolute address.
Start the positioning within specifications. Error location
information
and system
configuration
information
At END
instruction
execution, at
interrupt
occurrence
3641H Axis 1 command
speed error
The 32-bit range was exceeded when
the unit of the command speed was
converted.
Start the positioning within specifications. Error location
information
and system
configuration
information
At instruction
execution
3642H Axis 2 command
speed error
The 32-bit range was exceeded when
the unit of the command speed was
converted.
Start the positioning within specifications. Error location
information
and system
configuration
information
At instruction
execution
3643H Axis 3 command
speed error
The 32-bit range was exceeded when
the unit of the command speed was
converted.
Start the positioning within specifications. Error location
information
and system
configuration
information
At instruction
execution
3644H Axis 4 command
speed error
The 32-bit range was exceeded when
the unit of the command speed was
converted.
Start the positioning within specifications. Error location
information
and system
configuration
information
At instruction
execution
3651H Axis 1 error stop
(deceleration
stop)
When pulses were being output or
positioning was rising, the PLC
decelerated and stopped the pulse
output due to the limit of the moving
direction or writing during RUN. (The
PLSY instruction stops pulse output
immediately at both limits.)
Eliminate the error that has caused the stop
and restart the positioning.
Error location
information
and system
configuration
information
At END
instruction
execution, at
instruction
execution
3652H Axis 2 error stop
(deceleration
stop)
When pulses were being output or
positioning was rising, the PLC
decelerated and stopped the pulse
output due to the limit of the moving
direction or writing during RUN. (The
PLSY instruction stops pulse output
immediately at both limits.)
Eliminate the error that has caused the stop
and restart the positioning.
Error location
information
and system
configuration
information
At END
instruction
execution, at
instruction
execution
3653H Axis 3 error stop
(deceleration
stop)
When pulses were being output or
positioning was rising, the PLC
decelerated and stopped the pulse
output due to the limit of the moving
dire
ction or writing during RUN. (The
PLSY instruction stops pulse output
immediately at both limits.)
Eliminate the error that has caused the stop
and restart the positioning.
Error location
information
and system
configuration
information
At END
instruction
execution, at
instruction
execution
3654H Axis 4 error stop
(deceleration
stop)
When pulses were being output or
positioning was rising, the PLC
decelerated and stopped the pulse
output due to the limit of the moving
direction or writing during RUN. (The
PLSY instruction stops pulse output
immediately at both limits.)
Eliminate the error that has caused the stop
and restart the positioning.
Error location
information
and system
configuration
information
At END
instruction
execution, at
instruction
execution
3661H Axis 1 error stop
(immediately
stop)
When pulses were being output or
positioning was rising, the PLC stopped
the pulse output immediately by the
pulse stop command or detection of the
all outputs disable flag.
Eliminate the error that has caused the stop
and restart the positioning.
Error location
information
and system
configuration
information
At END
instruction
execution, at
instruction
execution
3662H Axis 2 error stop
(immediately
stop)
When pulses were being output or
positioning was rising, the PLC stopped
the pulse output immediately by the
pulse stop command or detection of the
all outputs disable flag.
Eliminate the error that has caused the stop
and restart the positioning.
Error location
information
and system
configuration
information
At END
instruction
execution, at
instruction
execution
Error
code
Error name Error details and cause Action Detailed
information
Diagnostic
timing