Configuring an M2PA System 120
Smart Media Software Configuration Guide 5 • Configuring SIGTRAN Applications
–Set a local index for the line
– Select a len
gth and an encoding scheme
–Click Cre
ate
Figure 164. Create New Line Interface
4. Verify that the "Line interface was successfully created" message is displayed.
Figure 165. Confirmation Message for New Line Interface
Understanding Parameters for Line Interfaces
Table 29. Configuration Parameters for New Line Interfaces
Parameter Description
Name Used by the Web Portal to indicate a specific object or string in the system
Type Defines the type of line interface: E1/DS3/T1/J1/STM1/OC3
Local Index Assigns an integer to represent an object
Length Indicates the physical length of a line: Short/Long/Autodetect/Monitoring
Encoding Sets an encoding scheme for a line interface. Values depend on the interface type:
E1:
DS3:
T1/J1:
STM1/OC3:
HDB3/AMI
B3ZS
B8ZS/AMI/AMI CLEAR
(None)