Patton electronic 07MSMARTMEDIA-SCG Universal Remote User Manual


 
Configuring the MTP3 Layer 89
Smart Media Software Configuration Guide 4 • Configuring SS7 Signaling
3. Configure the new point code:
–Enter a na
me for the point code
Select a point code ty
pe (select type-specific parameters)
Select a point code le
ngth (14, 16, 24 bits)
–Enter a po
int code
–Click Cre
ate
Figure 119. Creating the New MTP3 Point Code
4. Verify that the "Mtp3PointCode was successfully created" message displays, and the new point code
appears in the Point Codes list:
Figure 120. Successful Point Code Message
Understanding Parameters for SS7 Point Codes
Table 19. Configuration Parameters for New Point Codes
Parameter Description
Name Used by the Web Portal to indicate a specific object or string in the system
Type Defines the type of point code being created. Possible values: OPC/DPC/Mask
DPC Length Sets a format for the Destination Point Code (DPC) used by an object.
Possible values: 14bits format=3.8.3/16bits format=7.4.5/24bits format=8.8.8
Point Code Defines a point code by assigning it numerical values.